Description
Learn fundamentals of switchgear single-line diagrams, wirings, busbar and interlocking schematics, generator protection, operating GIS, transformer vector groups, etc. This bundle includes six courses in a total duration of 22 hours 42 mins. This bundle includes six courses in a total duration of 22 hours 42 mins.
This bundle includes the following courses. Click on each course to see the details:
Learn AC Distribution Panel Drawings: Single-Line Diagrams, Wirings, and Interlocking Schematics
A course dedicated to the design and analysis of an AC Distribution Panel (ACDB) and its components and proper schematics analysis. You will learn how to successfully read and analyze ACDB's single-line diagrams, wirings, and interlocking schematics. A case study is included. 18 lessons and 2h total course length.
Generator Protection Course: Concepts, Applications and Relay Protection Schemes
This course provides in-depth knowledge of the major electrical protection principles, applications and schemes associated with generators. Learn generator differential protection, restricted earth fault protection, negative sequence or unbalance protection, overcurrent protection, and many others. 42 Lectures and 5h 56m total course length.
Learn How to Operate and Analyze Interlocking Schemes for Substation & Gas Insulated Switchgear (GIS)
A complete understanding of the GIS substation standard operating procedure, interlocking schemes, sequence of operation for shutdown, trip & restoration which are the most critical topics for operating substation engineers. 12 lessons in 1h 36m total course length.
Mastering Transformer Vector Groups: Learn How To Analyze and Draw Windings Connections
This masterclass course provides a deep knowledge, understanding and analysis of transformer vector group connections and phasors. Learn to read and draw connections of transformer windings. The course consists of 15 lessons and 1h 36 min. total duration.
Mastering Power Substations: Electrical Equipment, Busbar Schemes and Relay Protection
This masterclass course provides a deep understanding and knowledge in power substations. You will learn different substation types, their differences, electrical equipment (switchgear, transformers, breakers, isolators, etc.) as well as busbar schematics and relay protection principles. The course consists in 97 lessons and 9h 2min total length.
Phasing in Power Substations: Principles, Techniques, and Real-World Applications
A course designed for engineers, technicians, and commissioning staff that thoroughly explores the principles, techniques, and practical applications of phasing in power substations, providing a systematic framework for comprehending its importance. The course consists of 14 lessons in duration of 2 hours and 32 minutes.

Phasing in Power Substations: Principles, Techniques, and Real-World Applications
Fundamentals of Power Generation, Transmission and Distribution Systems 



Reviews
There are no reviews yet.