Description
This course will teach you the fundamentals of electrical transformers in terms of electromagnetism, voltage and current transformation, ratios, and polarity, potential and current transformers, 3-phase transformer construction, transformer classifications, losses, and cooling, per unit, etc.
Electromagnetic forces interact with electrically charged particles and electromagnetic fields; this course will study how these forces lead to voltage and current transformation. Ratios and polarity are also studied leading to the introduction of potential transformers & current transformers, and their use in conjunction with the relevant instruments such as ammeters, voltmeters, wattmeters, and energy meters.
Overcurrent and restraint differential transformer protection is explained in detail, along with a look at some examples of “Old School relays” as well as modern IEDs (intelligent Electrical Devices).
Transformer Connections: (Y–Y; Delta-Delta; Y-Delta; Delta-Y and Y-Zag Zig) are examined along with Transformer Clock System Vector Nomenclature. Oil Analysis and the Buchholz Relay are also studied.
Course Summary
- Introduction
- The Ideal Transformer
- The Real Transformer
- Instrument Transformers (Current and Voltage)
- Three-Phase Power Transformers
- Transformer Clock System Vector Nomenclature
- Transformer Construction and Cooling
- Transformer Protection
- Transformer Relays
- The Final Exam With 24 Questions
For more information, please visit the course page:

Restricted Earth Fault Protection (REF) Course: Principles, Relays, Schematics and Settings
Transformer Differential Protection Course: Understanding Schematics, Relay Settings and Testing
Learn to Analyse Faults in Power Systems: Theoretical and Real-World Examples
Practical Course to Current Transformers (CTs): Specifications, Testing and Examples in Protection and Measuring Applications
Practical Course to Medium Voltage Infrastructure and Power Distribution
Practical Course to Ring Main Unit and Medium Voltage Cables in Ring Power Distribution Systems
Learn AC Distribution Panel Drawings: Single-Line Diagrams, Wirings, and Interlocking Schematics
Mastering Power Substations: Electrical Equipment, Busbar Schemes and Relay Protection
Power Engineering Course: Relay Control and Protection For LV/MV/HV Switchgear
AC Circuits Analysis: Real, Reactive and Complex Power Calculation
Gas-Insulated Switchgear Course: Design, Installation, Operation and Maintenance, Testing
Advanced Course in Proper Grounding and Fault Mitigation
Symmetrical Components of Three-Phase Power Analysis and Fault Studies 