Course Description
In this course, you will learn how to calculate voltage drop in single phase, balanced three-phase and unbalanced three-phase power systems. You will learn short circuit calculations with two different methods namely “Fault impedance method” and “Symmetrical Components method“.
You will also learn per unit system for short circuit current calculations.
Course Summary
- Voltage Drop Analysis
- Fault Current Analysis – Fault Impedance Method
- Symmetrical Components Method
- Capacitive Fault Currents in Line-to-Ground Faults
Who Is This Course For
Basic electrical circuit theory knowledge
Requirements
Electrical engineers, technicians, electrical engineering students, anyone who wants to learn electrical power networks
Downloadable course materials
After purchasing the course, students can download the following documents and tools:
- Course Slides: Voltage Drop Analysis (PPTX)
- Course Slides: Fault Current Analysis – Fault Impedance Method (PPTX)
- Course Slides: Fault Current Analysis – Symmetrical Components Method (PPTX)
- Course Slides: Capacitive Fault Currents in Line-to-Ground Faults (PPTX)
- Voltage drop calculations: Formulas, phasor diagram and real-world examples (PDF)
- Voltage drop calculations and design of urban distribution feeders (PDF)
- Voltage drop calculations: MS Excel Spreadsheet (XLSX)
- Motor Voltage Drop Calculator: MS Excel Spreadsheet (XLSX)
Course Content
About Instructor
Low Voltage Distribution and Lighting Design Bundle: AutoCAD, Dialux, Excel (Course + Coursebook)
Low Voltage Power Distribution Course For Beginners
Electrical Designing and Drafting Course (Part 2)
Mastering Transformer Vector Groups: Learn How To Analyze and Draw Windings Connections
Power System Analysis, Modelling, Load Flow and Fault Studies for True Engineers
Mastering Power Substations: Electrical Equipment, Busbar Schemes and Relay Protection
Gas-Insulated Switchgear Course: Design, Installation, Operation and Maintenance, Testing
Understanding the Concepts Behind Power System Reliability
A Detailed Course to Wave Energy Conversion For True Engineers: Theory and System Implementation
Learn How to Perform Calculations of Electrical Loads and Design the Protection System
Relay Control and Protection Bundle: Complete Relay Circuitry and Schematics (Five Courses)
Practical Course to Ring Main Unit and Medium Voltage Cables in Ring Power Distribution Systems
The Essentials of Capacitor Banks: Connections, Calculations and Relay Protection
Electrical Designing and Drafting Bundle (Two Courses)
Power Engineering Course: Relay Control and Protection For LV/MV/HV Switchgear
Generation and Measurements of High Voltage and Overhead Transmission Line Insulators
Course to Relay Circuitry and Understanding Control and Protection Schematics
MATLAB Simulations using Simulink for Power Electronics, Electric Motors, Generators and Solar
Complete Power Engineering Bundle (Six Courses)
Advanced Electrical Machines MasterClass: Examples, Industrial Applications and Troubleshooting
MATLAB/Simulink for Analog and Digital Electronics
Circuit Breaker Failure Protection Course: Function, CB Scheme/Trip Matrix and Various Busbar Schemes