Course Description
Planning of an electrical design project starts with power calculations. This is always the first step in dimensioning a low voltage power system.
Simaris Design is, according to our experience, by far the best software to quickly set up a project, create single-line diagrams, and output all the needed documents (project documentation, different list in Excel, e.g. busbar, cable, device settings, selectivity documentation, etc., single-line diagrams in PDF and DWG/DXF).
When creating single line diagrams in Simaris Design the devices you use are grouped into three categories:
- System infeed: (transformer with primary and secondary side, transformer only with secondary side, coupling to use when you have also emergency power supply, like a diesel aggregate (generator) etc.)
- Distribution boards: (with busbars, without busbar, sub-distribution boards etc.)
- Final circuits: (electrical consumers) ranging from general devices, motors (including DOL, soft starter, reverse-duty and frequency converter), power outlets up to special dummy loads. You even have a possibility to insert a charging unit for electric cars.
SIMARIS design options:
- Thanks to the option to visualize and calculate parallel network operation, different power sources such as transformers and generators can be operated in the same network.
- In the context of automatic selectivity evaluation, selectivity thresholds are displayed in addition to the characteristic current-time curve and the corresponding envelope curves.
- There is the option to analyse and optimize the energy efficiency of the network to be designed.
- The representation of an active and passive changeover in the safety supply is possible owing to the integration of general and directed couplings into the network diagram (sub-distribution level included).
- Distribution boards can be mapped as equivalent impedances which can be incorporated into the calculation, acting as substitutes for parts of the network which cannot yet be specified more precisely.
We highly recommend this software to all of you who work in the electrical engineering field.
Course Summary
- Download, install and register Simaris Design and Simaris Curves
- First steps in Simaris – workspace, sections, settings
- Basic and advanced single line diagrams
- Dimensioning power cables (including special topic – harmonic content)
- Tips & Tricks on Simaris Design and Simaris Curves and recapitulation
Who Is This Course For
- Students of electrical engineering
- Electricians, Engineers, Technicians
- Maintenance department in factories when planning new investments in production
- Construction site engineers to quickly plan and dimension their low voltage installation
- Engineering offices when desinging new electrical and automation systems
- Anyone who needs ocasional dimensioning of their low voltage installations
Requirements
Student needs to understand the basics of power calculations.
Course Content
About Instructor
Low Voltage Distribution and Lighting Design Bundle: AutoCAD, Dialux, Excel (Course + Coursebook)
Low Voltage Power Distribution Course For Beginners
Electrical Designing and Drafting Course (Part 2)
Mastering Transformer Vector Groups: Learn How To Analyze and Draw Windings Connections
Power System Analysis, Modelling, Load Flow and Fault Studies for True Engineers
Mastering Power Substations: Electrical Equipment, Busbar Schemes and Relay Protection
Gas-Insulated Switchgear Course: Design, Installation, Operation and Maintenance, Testing
Understanding the Concepts Behind Power System Reliability
A Detailed Course to Wave Energy Conversion For True Engineers: Theory and System Implementation
Learn How to Perform Calculations of Electrical Loads and Design the Protection System
Relay Control and Protection Bundle: Complete Relay Circuitry and Schematics (Five Courses)
Practical Course to Ring Main Unit and Medium Voltage Cables in Ring Power Distribution Systems
The Essentials of Capacitor Banks: Connections, Calculations and Relay Protection
Electrical Designing and Drafting Bundle (Two Courses)
Power Engineering Course: Relay Control and Protection For LV/MV/HV Switchgear
Generation and Measurements of High Voltage and Overhead Transmission Line Insulators
Course to Relay Circuitry and Understanding Control and Protection Schematics
MATLAB Simulations using Simulink for Power Electronics, Electric Motors, Generators and Solar
Complete Power Engineering Bundle (Six Courses)
Advanced Electrical Machines MasterClass: Examples, Industrial Applications and Troubleshooting
MATLAB/Simulink for Analog and Digital Electronics
Circuit Breaker Failure Protection Course: Function, CB Scheme/Trip Matrix and Various Busbar Schemes