Did you know that the Enterprise Membership plan includes a 50% OFF on all courses? Dismiss
No products in the cart.
Learn how to use real, reactive, and complex power in the analysis of AC circuits. Learn how to calculate power factor correction (PFC) and power in three-phase circuits. 9 lessons in 3h 38min total course length.
Learn the basic concepts of fault studies using symmetrical components on HV three-phase power systems. The final exam and certification are included. 9 lessons in 3h 47min total course length.
Learn how to use the method of symmetrical components to simplify asymmetrical three-phase power analysis and understand fault studies and protection schemes. 7 lessons in 1h 30m total course length.
Learn what Per Unit Analysis is and how manufacturers of electrical equipment use it to rate their equipment. Later, you will use it in your power flow, short circuit evaluation and motor starting studies. 10 lessons in 6h 5min total course length.
This course covers electromagnetism, voltage and current transformation, ratios & polarity, potential & current transformers, 3-phase transformer construction, transformer classifications, losses & cooling, per unit, etc. 9 lessons in 5h 37min total course length.
This course deals with the protection and control principles of high voltage power stations and major equipment like transformers, circuit breakers, CTs and VTs. Instantaneous, overcurrent and transformer differential protection are studied. 10 sections in 5h 23min total course length.
This course takes you from the fundamentals of trigonometry to the more sophisticated operations required in electrical engineering. 10 sections, 3h 47min total course length.
Learn fundamentals of instrument and single-phase/three-phase metering in utilities and industry, digital & analog wattmeters, Kwhr meters. 8 lessons in 4h 7min total course length.
This is course is dedicated to digital logic which is the foundation for modern relay protection and IEDs (Intelligent Electrical Devices). You will learn binary numbers and binary arithmetic, logic gates and switches, and combinational logic functions. 6 chapters in 2h 8 min. total course length.
This course will provide the student with the basic understanding of working with circuits involving Alternation Current, which includes sinusoidal waveforms, vectors and phasors. The final exam and certification are included. 5 sections, 3h 2min total course length.
Learn everything about AC electric circuits and electronics, from the basics such as what sinusoids are, all the way to key characteristics of AC circuits such as impedance, admittance, power factor, complex power, and power calculations.
Learn how to simulate any analog or digital electronics device in MATLAB/Simulink, including active low-pass & high-pass filters, audio equalizers, inverting & non-inverting amplifiers, analog-to-digital converters (ADCs), and digital-to-analog converters (DACs). 5 sections, 34 lectures in 6h 18m total length.
This course provides a complete overview of one of the main areas of electrical engineering and power engineering: rectifiers, DC-to-DC converters, and inverters. 25 lectures and 1 exam in 3h 43m total course length.
Learn how to simulate any power electronics device in MATLAB/Simulink, including rectifiers, DC-to-DC converters, and inverters (single-phase and three-phase). It consists of 4 sections, 30 lectures in 6h 22m total course length.
Learn about power flow analysis and short circuit analysis of balanced and unbalanced faults to further your career in electrical and power engineering. Examples are solved to illustrate how to analyze real-world power systems. 4 sections, 37 lectures in 5h 48m total course length.
Learn about steady-state and transient stability of power systems and their importance in the safe and reliable operation of power systems.
Learn how to simulate power systems in MATLAB/Simulink by building several Simulink power system models for load flow, short circuit, and power stability studies) and analyze the behavior of the system under several conditions.
Learn the essentials of generators, transformers, and transmission lines and their use in power system analysis to further your career in electrical and power engineering. The course consists of 35 lectures in 4h 36m total length.
Learn the fundamentals of power system analysis: power analysis of single- and three-phase AC circuits, power triangle, complex power, and power flow, delta or wye connected loads and per-phase analysis of balanced loads. The course consists of 20 lectures in 2h 51m total length.
Learn fundamentals of electric circuits and electronics, starting from the basics such as what an electric circuit is, electrical quantities like voltage, current & power, all the way to analyzing electric circuits.
Learn how to perform various electrical calculations and to use AutoCAD from scratch to professional level (real project included in DWG) in your residential and commercial projects. This course has 7 lessons, 87 topics in 6h 55m total course length.
Learn from scratch to design residential and commercial projects with electrical transformers, diesel gensets, UPSs, batteries, etc. (electrical theory included). 33 lectures in 6h 56m total length.
This course tackles the most important aspects of a power substation (basic theory, electrical equipment, earthing, and design guidelines). It consists of 3 lessons, 29 topics in 5h 01m total course duration.