Did you know that the Enterprise Membership plan includes a 50% OFF on all courses? Dismiss
No products in the cart.
Learn how to depict single-line, three-line diagrams and graphic electrical components that figure on them. Learn switchgear and substation elements like a circuit breaker, isolator, earth-switch, power transformer, CTs/VTs, arrestor, etc. 16 lessons in 3h 37 minutes total course length.
Learn how electrical installations are done on-site during execution stages. Learn how cable conduits are installed and how distribution boards and capacitor banks are wired and installed. Find out how light fixtures & power sockets are installed. 38 lessons in 3 hours 38 mins.
Learn power system modelling and analysis using ETAP software and its functionalities for successful design & solving various power system practical problems. Learn how to simulate and analyze the steady-state and dynamic power system. 29 topics in 8h 56m total course length.
Learn in detail Restricted Earth Fault (REF) protection and its installation, connections & schematics (for transformer, motor, generator, shunt reactor and autotransformer), calculations and protection requirements. An example of a real REF relay is included. 19 lessons in 3h 14 min.
This course is one of the essential courses for electrical engineers. It explains the theory behind capacitor banks, their series and parallel connections, protection and much more. The course is based on the use of capacitor banks in the field. 8 lessons in 1 hour 41 min.
Learn how substation buses operate and how to implement different protective elements for their protection. Learn to design robust protection schemes to protect these components from faults and abnormal operating conditions. 2h 27m total course length.
Learn about power system protection philosophy and techniques, and how to analyze relaying schemes of power systems, including instrument transformers, transmission lines, power transformers, and generators. 6h 16m total course length.
Learn how to analyse unsymmetrical power system faults and master two of the most fundamental and necessary types of mathematics for relay engineers and technicians: Symmetrical components and the per-unit system. 36 lessons in 7h 7m total course length.
Electrical Power and Light Design Coursebook is a comprehensive guide to the distribution of power & lighting using AutoCAD, DIALux and MS Excel (PDF guide included). 8 chapters, quiz, 211 pages.
This is an intermediate to advance level course dedicated to schematics and control wiring diagrams of high-voltage and medium-voltage circuit breakers (applicable to power substations, switchyards, power plants, etc.). 39 lessons in 7h 14min total course length.
In-depth analysis of the fundamental issues in the power quality discipline considering related standards, practical case studies. 8 lessons in 3h 28m total course length.
Learn how batteries work, different battery designs and types, terminology, operations (series, parallel, primary, secondary etc.)., hazards, and a lot more. 55 lectures in 2h 30m total course length.
Learn electrical transformers from the scratch. Starting from theory, transformer types, designs and applications, to cooling systems, components, tap changers, Buchholz relay, and so much more. 30 lessons in 2h 50m total course length.
Learn how to wire and set frequency converter parameters both open and close loop applications. Without any knowledge of frequency converters you will be able to draw a wiring diagram, connect and set frequency converter into operation. 10 lessons in 3h 8min. total course length.
Learn about three-phase asynchronous motors, starting curve and importance of the motor smooth start, soft starter features and wiring diagrams. 5 lessons in 53m total course length.