Did you know that the Enterprise Membership plan includes a 50% OFF on all courses? Dismiss
No products in the cart.
This course provides a knowledge in power system modeling and analysis by utilizing the ETAP program and its features. The course covers the analysis of arc-flash, transient stability, motor accelerating, short-circuit, harmonics, as well as the protection example, earthing analysis and an example of renewable energy sources. The course consists of a total of 34 lessons and has a duration of 5 hours and 29 minutes.
This masterclass course provides a deep understanding and knowledge in power substations. You will learn different substation types, their differences, electrical equipment (switchgear, transformers, breakers, isolators, etc.), as well as busbar schematics and relay protection principles. The course consists in 97 topics and 9h 2min total length.
This course has been carefully designed to educate true electrical engineers with the knowledge and skills required to create resilient lightning protection systems. It consists of 49 lessons in total duration of 16 hours 50 minutes.
Learn all kinds of transformer you can find in various electrical networks, their design, where they are applied, how they are protected, and how to test and perform diagnostics. The course consists of 17 lessons and 163 topics. It takes 26 hours and 18 minutes in total duration.
This course brings in-depth insight into wave energy conversion and the practice of implementation in the real world. Learn how to satisfy the requirements imposed by the network and many other things. The course consists of 3 sections, 26 lectures and 6h 22m total length.
Learn everything about power system analysis, single-phase and three-phase electric systems, designing and modeling generators, transformers, and transmission lines. The power system study comprises load flow studies and fault analyses. 121 lectures in 21h 41m total course length.
This masterclass course provides a deep knowledge, understanding and analysis of various schematics of an medium-voltage switchgear, such as tripping, trip circuit supervision, interlocking, indication circuits, and many others. Detailed diagrams of common feeder types are included. 5 chapters, 74 lessons in 12h 50min. total course length.
Learn the essentials of wind power systems, their working principle, wind turbine characteristics, speed control, calculation and simulation. Recommended for electrical engineers, wind turbine technicians and other engineers. 59 lesson in 8h 43m total course length included.
This course provides in-depth knowledge of the major electrical protection principles, applications and schemes associated with generators. Learn generator differential protection, restricted earth fault protection, negative sequence or unbalance protection, overcurrent protection, and many others. 42 Lectures and 5h 56m total course length.
A course dedicated to the design and analysis of an AC Distribution Panel (ACDB) and its components and proper schematics analysis. You will learn how to successfully read and analyze ACDB's single-line diagrams, wirings, and interlocking schematics. A case study is included. 18 lessons and 2h total course length.
Learn the essentials of high voltage generation & measurement methods, operation of HV testing transformer, overhead transmission line insulators, and much more. The course consists of 49 lessons and 5h 1m total length.
Learn how to perform power system modeling and power system stability analysis using ETAP. The course covers generator dynamics & transient stability analysis, synchronism of generating sources, and many other important lessons. 23 lectures in 3h 35m total course length.
Learn the fundamentals of induction motor dynamics, motor acceleration analysis, and motor starting methods (Autotransformer, Star-Delta) in ETAP software. 10 sections and 19 lectures in 3h 19m total course length.
Learn the fundamentals of wind energy systems with step by step examples without any previous knowledge. Learn how to design and specify wind turbine and its electrical equipment. The course consists of 64 lectures in 11h 14m total length and plenty of downloadable materials.