Save 20% on All Courses and PRO Membership Plan with a coupon BLACKFRIDAY. Dismiss
Subtotal: 56.90 $
View cartCheckout
This course brings in-depth insight into wave energy conversion and the practice of implementation in the real world. Learn how to satisfy the requirements imposed by the network and many other things. The course consists of 3 sections, 26 lectures and 6h 22m total length.
Learn everything about power system analysis, single-phase and three-phase electric systems, designing and modeling generators, transformers, and transmission lines. The power system study comprises load flow studies and fault analyses. 121 lectures in 21h 41m total course length.
This masterclass course provides a deep knowledge, understanding and analysis of various schematics of an medium-voltage switchgear, such as tripping, trip circuit supervision, interlocking, indication circuits, and many others. Detailed diagrams of common feeder types are included. 5 chapters, 74 lessons in 12h 50min. total course length.
Learn the essentials of wind power systems, their working principle, wind turbine characteristics, speed control, calculation and simulation. Recommended for electrical engineers, wind turbine technicians and other engineers. 59 lesson in 8h 43m total course length included.
This course provides in-depth knowledge of the major electrical protection principles, applications and schemes associated with generators. Learn generator differential protection, restricted earth fault protection, negative sequence or unbalance protection, overcurrent protection, and many others. 42 Lectures and 5h 56m total course length.
A course dedicated to the design and analysis of an AC Distribution Panel (ACDB) and its components and proper schematics analysis. You will learn how to successfully read and analyze ACDB's single-line diagrams, wirings, and interlocking schematics. A case study is included. 18 lessons and 2h total course length.
Learn the essentials of high voltage generation & measurement methods, operation of HV testing transformer, overhead transmission line insulators, and much more. The course consists of 49 lessons and 5h 1m total length.
Learn how to perform power system modeling and power system stability analysis using ETAP. The course covers generator dynamics & transient stability analysis, synchronism of generating sources, and many other important lessons. 23 lectures in 3h 35m total course length.
Learn the fundamentals of induction motor dynamics, motor acceleration analysis, and motor starting methods (Autotransformer, Star-Delta) in ETAP software. 10 sections and 19 lectures in 3h 19m total course length.
Learn the fundamentals of wind energy systems with step by step examples without any previous knowledge. Learn how to design and specify wind turbine and its electrical equipment. The course consists of 64 lectures in 11h 14m total length and plenty of downloadable materials.
Learn how to depict single-line, three-line diagrams and graphic electrical components that figure on them. Learn switchgear and substation elements like a circuit breaker, isolator, earth-switch, power transformer, CTs/VTs, arrestor, etc. 16 lessons in 3h 37 minutes total course length.
Learn how electrical installations are done on-site during execution stages. Learn how cable conduits are installed and how distribution boards and capacitor banks are wired and installed. Find out how light fixtures & power sockets are installed. 38 lessons in 3 hours 38 mins.
Learn power system modelling and analysis using ETAP software and its functionalities for successful design & solving various power system practical problems. Learn how to simulate and analyze the steady-state and dynamic power system. 29 topics in 8h 56m total course length.
Learn in detail Restricted Earth Fault (REF) protection and its installation, connections & schematics (for transformer, motor, generator, shunt reactor and autotransformer), calculations and protection requirements. An example of a real REF relay is included. 19 lessons in 3h 14 min.