Did you know that the Enterprise Membership plan includes a 50% OFF on all courses? Dismiss
No products in the cart.
This course is a step-by-step guide on performing various load calculations and analyses dedicated to power engineers. It covers load and thermal current calculations, cable sizing, voltage drop, short circuit calculations, and circuit breaker & transformer sizing. The course consists of 19 lessons in 7 hours 41 min. duration.
This course provides everything about distribution systems design needed for electrical engineering beginners. It comprises lighting design, wiring of electrical components, circuit breaker selection, selectivity and cascading, distribution transformers, power cables, short circuit analysis and voltage drop calculations, power factor, etc. 54 lessons in total duration of 11h 15min.
This course has been carefully designed to educate true electrical engineers with the knowledge and skills required to create resilient lightning protection systems. It consists of 49 lessons in total duration of 16 hours 50 minutes.
Learn the fundamentals of induction motor dynamics, motor acceleration analysis, and motor starting methods (Autotransformer, Star-Delta) in ETAP software. 10 sections and 19 lectures in 3h 19m total course length.
Learn the fundamentals of wind energy systems with step by step examples without any previous knowledge. Learn how to design and specify wind turbine and its electrical equipment. The course consists of 64 lectures in 11h 14m total length and plenty of downloadable materials.
Learn how to depict single-line, three-line diagrams and graphic electrical components that figure on them. Learn switchgear and substation elements like a circuit breaker, isolator, earth-switch, power transformer, CTs/VTs, arrestor, etc. 16 lessons in 3h 37 minutes total course length.
Learn how electrical installations are done on-site during execution stages. Learn how cable conduits are installed and how distribution boards and capacitor banks are wired and installed. Find out how light fixtures & power sockets are installed. 38 lessons in 3 hours 38 mins.
Electrical Power and Light Design Coursebook is a comprehensive guide to the distribution of power & lighting using AutoCAD, DIALux and MS Excel (PDF guide included). 8 chapters, quiz, 211 pages.
Learn how batteries work, different battery designs and types, terminology, operations (series, parallel, primary, secondary etc.)., hazards, and a lot more. 55 lectures in 2h 30m total course length.
Learn how to plan and design low-voltage power distribution systems using this powerful (and free of charge) software from Siemens. 12 lessons in 1h 25m total course length.
Learn to design electrical drawings using AutoCAD, DiaLUX, and ETAP software, as well as to perform voltage drop calculation and short-circuit analysis. 64 lectures in 8h 5m total course length.
Learn fundamentals of a programming ladder diagram for PLC by using the LogixPro simulator for electrical power and industrial engineering. 32 lectures in 6h 30m total course length.
This course is designed for electrical engineering students to learn about low-current systems: fire alarm, CCTV, telephone, MATV, data and sound systems. 16 lectures in 4h 18m total course length.
Learn everything about AC electric circuits and electronics, from the basics such as what sinusoids are, all the way to key characteristics of AC circuits such as impedance, admittance, power factor, complex power, and power calculations.
Learn how to perform various electrical calculations and to use AutoCAD from scratch to professional level (real project included in DWG) in your residential and commercial projects. This course has 7 lessons, 87 topics in 6h 55m total course length.
Learn from scratch to design residential and commercial projects with electrical transformers, diesel gensets, UPSs, batteries, etc. (electrical theory included). 33 lectures in 6h 56m total length.
Learn to design low voltage distribution systems using AutoCAD and Dialux (power distribution, lighting, voltage drop, earthing and other calculations). 62 lectures in 10h total course length.