Capacitors in Power Systems

For the reduction of cost and improved reliability, most of the world’s electric power systems continue to be interconnected. Interconnections take advantage of diversity of loads, availability of sources and fuel price for supplying power to loads at minimal cost.

Use of capacitors to regulate the voltage in electrical networks
Use of capacitors to regulate the voltage in electrical networks (photo credit: Greiner Schaltanlagen GmbH)

Compensation in power systems is, therefore, essential to alleviate some of these problems. Series/shunt compensation has been in use for the past many years to achieve this objective.

Load compensation is the management of reactive power to improve power quality i.e. voltage profile and power factor. The reactive power flow is controlled by installing shunt compensating devices (capacitors/reactors) at the load end bringing about proper balanced between generated and consumed reactive power.

On power systems, capacitors do not store their energy very long—just one-half cycle. Each half cycle, a capacitor charges up and then discharges its stored energy back into the system. The net real power transfer is zero. Just when a motor with low power factor needs power from the system, the capacitor is there to provide it.

Then, in the next half cycle, the motor releases its excess energy, and the capacitor is there to absorb it.

Capacitors and reactive loads exchange this reactive power back and forth. This benefits the system because that reactive power (and extra current) does not have to be transmitted from the generators all the way through many transformers and many kilometers of lines. The capacitors can provide the reactive power locally. This frees up the lines to carry real power, power that actually does work.

Capacitor units are made of series and parallel combinations of capacitor packs or elements put together as shown in Figure 1.

Capacitor bank elements and kvar meter
Figure 1 – Capacitor bank elements and kvar meter

Capacitors are made within a given tolerance. The IEEE standard allows reactive power to range between 100% and 110% when applied at rated sinusoidal voltage and frequency (at 25°C case and internal temperature) (IEEE Std. 18-2002).

In practice, most units are from +0.5% to +4.0%, and a given batch is normally very uniform.

Capacitor losses are typically on the order of 0.07 to 0.15 W/kVAr at nominal frequency. Losses include resistive losses in the foil, dielectric losses, and losses in the internal discharge resistor.

Capacitors must have an internal resistor that discharges a capacitor to 50 V or less within 5 min when the capacitor is charged to the peak of its rated voltage. This resistor is the major component of losses within a capacitor.

Capacitors have very low losses, so they run very cool. But capacitors are very sensitive to temperature and are rated for lower temperatures than other power system equipment such as cables or transformers.

Also, capacitors are designed to operate at high dielectric stresses, so they have less margin for degraded insulation. Standards specify an upper limit for application of 40°C or 46°C depending on arrangement.

These limits assume unrestricted ventilation and direct sunlight. At the lower end, IEEE standard 18 specifies that capacitors shall be able to operate continuously in a −40°C ambient.

Title:Use of capacitors to regulate the voltage in electrical networks – Seminar paper – Gentrit Rexha at University at Ljubljana, Faculty Of Electrical Engineering
Format:PDF
Size:1.50 MB
Pages:35
Download:Right here | Video Courses | Membership | Download Updates
Use of capacitors to regulate the voltage in electrical networks
Use of capacitors to regulate the voltage in electrical networks

Premium Membership

Get access to premium HV/MV/LV technical articles, advanced electrical engineering guides, papers, and much more! It will help you to shape up your technical skills in your everyday life as an electrical engineer.
50% Discount 💥 - Save 50% on all 90+ video courses with Enterprise Membership plan.

More Information

2 Comments


  1. GODWIN
    Jun 03, 2022

    Can capacitor stabilize output power supply in area where the input voltages are not stable ?


  2. KANTE MAMADOU
    Jun 06, 2020

    BONJOUR,
    je suis le directeur d’une société de prestation de service Electricité au Burkina Faso.
    votre thème de compensation avec les condensateurs est vraiment top.
    vous commercialiser le câblage dans le coffret??

Leave a Reply to GODWIN

Tell us what you're thinking. We care about your opinion! Please keep in mind that comments are moderated and rel="nofollow" is in use. So, please do not use a spammy keyword or a domain as your name, or it will be deleted. Let's have a professional and meaningful conversation instead. Thanks for dropping by!

  ⁄  one  =  6

Learn How to Design Power Systems

Learn to design LV/MV/HV power systems through professional video courses. Lifetime access. Enjoy learning!

Subscribe to Weekly Newsletter

Subscribe to our Weekly Digest newsletter and receive free updates on new technical articles, video courses and guides (PDF).
EEP Academy Courses - A hand crafted cutting-edge electrical engineering knowledge