Substation theory and practice

An electrical substation is a subsidiary station of an electricity generation, transmission and distribution system where voltage is transformed from high to low or the reverse using transformers. Electric power may flow through several substations between generating plant and consumer, and may be changed in voltage in several steps.

Power substation guides, research papers and studies
Power substation guides, research papers and studies (on photo: Ghana Aboadze 330kV substation)

A substation that has a step-up transformer increases the voltage while decreasing the current, while a step-down transformer decreases the voltage while increasing the current for domestic and commercial distribution. The word substation comes from the days before the distribution system became a grid.

The first substations were connected to only one power station where the generator was housed, and were subsidiaries of that power station.


Equipment in substation

Substations generally have switching, protection and control equipment and one or more transformers. In a large substation, circuit breakers are used to interrupt any short-circuits or overload currents that may occur on the network. Smaller distribution stations may use recloser circuit breakers or fuses for protection of distribution circuits. Substations do not usually have generators, although a power plant may have a substation nearby.

Other devices such as power factor correction capacitors and voltage regulators may also be located at a substation.

Substations may be on the surface in fenced enclosures, underground, or located in special-purpose buildings.

High-rise buildings may have several indoor substations. Indoor substations are usually found in urban areas to reduce the noise from the transformers, for reasons of appearance, or to protect switchgear from extreme climate or pollution conditions.

Where a substation has a metallic fence, it must be properly grounded (UK: earthed) to protect people from high voltages that may occur during a fault in the network.

Earth faults at a substation can cause a ground potential rise. Currents flowing in the Earth’s surface during a fault can cause metal objects to have a significantly different voltage than the ground under a person’s feet; this touch potential presents a hazard of electrocution.

Browse guides and papers

Note that all documents in this section are free to download. Navigate through sub-pages to discover all documents.

Fault Finding Solutions Guide by MEGGER

When voltage is impressed across any insulation system, some current leaks into, through, and around the insulation. When testing with DC high voltage, capacitive charging current, insulation absorption current, insulation leakage current, and by-pass current… Read more

Jul 01, 2012

Megger - Fault Finding Solutions

Protection of electrical networks

Generally, with an HV power supply, a private distribution network comprises (see Figure 1-1): An HV consumer substation fed by one or more sources and made up of one or more busbars… Read more

May 05, 2012

Protection of Electrical Networks

Design Guide for Rural Substations

This bulletin covers rural transmission and distribution with air-insulated, outdoor substations 345 kV (phase-to-phase) and below. Possible design responsibilities of the engineer are covered, including preparation of construction drawings, material,… Read more

Mar 23, 2012

Design Guide for Rural Substations

Electric Power Substations Engineering

Today’s state-of-the-art HVDC and FACTS controls fully digitized and processor based allow steady-state, quasi steady-state, dynamic, and transient control actions and provide important equipment and system protection functions. Fault monitoring… Read more

Feb 11, 2012

Power Plant Accoustic

This manual presents a review of applicable sound and vibration-level criteria, sound level data for reciprocating and turbine-type engines driven by gas and liquid fuels, a basic approach for evaluating… Read more

Oct 03, 2010

Applying an Ethernet LAN in a Substation

This paper is a discussion of an NSTAR Electric & Gas Corp. project using current Ethernet technology to build a Local Area Network (LAN) in a single substation application. NSTAR’s… Read more

Oct 03, 2010

Applying an Ethernet LAN in a Substation

55 Comments


  1. Nanle bitrus
    Sep 14, 2020

    You really improve my ideas in power


  2. Rex Gasinore
    Jul 09, 2020

    Learn more to understand what is all about Electrical Technology..


  3. B.H. Merzayi
    Jun 03, 2020

    Hi dear!
    Please, send information about RTCC panel for a 110kV /20kv substation
    thank you.


  4. DAVIS CHESOLI
    Mar 21, 2020

    i would like to be a regular contributor to most discussions in electrical engineering. Specifically in areas of protection, Reliability engineering and alternative energy. Am an electrical engineer by training with over 30 years of expereince both in the academic and industry.


  5. Satish Bedi
    Jan 11, 2020

    i have lot of ideas for Electrical energy conservation which i had tested and result is good


  6. Godswill Essienta
    Aug 18, 2019

    you guys are unique, i want to be part of this vision, thanks.


  7. FRANCIS
    Aug 01, 2019

    hi am francis from bonum kenya limited
    kindly see your email and let me know what item you manufacture
    regards
    francis


  8. Agaba Emmanuel
    Jun 07, 2019

    I wish to subscribe to this portal,thanks

Leave a Reply to Nanle bitrus

Tell us what you're thinking... we care about your opinion!

  −  4  =  five

Electrical Engineering Courses

Learn to design electrical power and industrial automation systems through professional video courses.
Protection testing