The essentials of electric shock protection, earthing systems and RCDs
Protection of persons and livestock against electric shock is a fundamental principle in the design of electrical installations in accordance with BS 7671: Requirements for Electrical Installations, commonly known as… Read more
Aug 21, 2017 | By Edvard Csanyi
10 equipment you MUST recognize in every distribution substation
Distribution substation is a substation from which electric supply is distributed to the different users. In a substation there are numbers of incoming and outgoing circuits each having its isolator,… Read more
Aug 11, 2017 | By Edvard Csanyi
How to install a manual transfer switch for a backup system in 16 steps
A manual transfer switch is installed next to the main service panel to override the normal electrical service with power from a backup generator during a power outage. Manual transfer… Read more
Aug 02, 2017 | By Edvard Csanyi
20 Simple Questions to Check Your Overcurrent Protection Knowledge
As you already know, reliable overcurrent protective devices, such as fuses and circuit breakers, prevent or minimize costly damage to transformers, conductors, motors, equipment, and the other many components and… Read more
Jul 31, 2017 | By Edvard Csanyi
Unbalance protection of grounded & ungrounded wye shunt capacitor banks
The protection of shunt capacitor banks against internal faults involves several protective devices in a coordinated scheme. Typically, the protective elements found in a shunt capacitor banks (SCB) for internal… Read more
Jul 26, 2017 | By Edvard Csanyi
Easy understanding of 3-phase transformer connections (Delta–Delta, Wye–Wye, Delta–Wye and Wye–Delta)
Three-phase voltage transformations can be accomplished by using three phase transformers, which are single devices with all windings constructed on a single iron core. They also can be accomplished by… Read more
Jul 14, 2017 | By Edvard Csanyi
Power quality monitoring with line disturbance analyzers and voltage recorders
Many power quality problems are caused by inadequate wiring or improper grounding. These problems can be detected by simple examination of the wiring and grounding systems. Another large population of… Read more
Jul 03, 2017 | By Edvard Csanyi
Did you test your electrician’s skills recently? Take the quiz. It’s time!
It’s always a good idea to put the sparks into your memory and shed light on things you have learned years ago. Whether you are a rookie in a field… Read more
Jun 07, 2017 | By Edvard Csanyi
Never underestimate electrostatic discharge (ESD) while working with data networking equipment
Let’s start with basics you probably already know, but nevertheless. It’s important to explain the basics first. Electrostatic Discharge (or ESD) refers to the transfer of electrostatic charge between bodies… Read more
Mar 08, 2017 | By Edvard Csanyi
Performing power factor test on dry-type transformer during commissioning
The power factor test is a maintenance test used to determine the insulation system dielectric power loss by measuring the power angle between an applied AC voltage and the resultant… Read more
Mar 01, 2017 | By Edvard Csanyi
Basic electrical design of a PLC panel (Wiring diagrams)
It is uncommon for engineers to build their own PLC panel designs (but not impossible of course). For example, once the electrical designs are complete, they must be built by… Read more
Feb 27, 2017 | By Edvard Csanyi
High voltage station – Design, construction and commissioning process
Having selected the right site location for high voltage station, the design construction and commissioning process would broadly follow the steps shown in Figure 1. Recent trends in utilities have… Read more
Nov 11, 2016 | By Edvard Csanyi
Five key factors to the correct cable selection and application
It is essential to know cable construction, characteristics, and ratings to understand problems related to cable systems. However, to correctly select a cable system and assure its satisfactory operation, additional… Read more
Oct 31, 2016 | By Edvard Csanyi
What a ground fault circuit interrupter does and what it does not do
A ground fault circuit interrupter (GFCI) monitors the current balance between the ungrounded “hot” conductor and the grounded conductor. As soon as the current flowing through the “hot” conductor is in… Read more
Sep 09, 2016 | By Edvard Csanyi
Answer 20 questions correctly and prove you are good electrician
It’s not easy to be a good electrician, that’s for sure. Things you studied hard (or still studying) are gradually being forgotten, especially electrical formulas. Well, these 20 questions tend… Read more
Sep 02, 2016 | By Edvard Csanyi